Application / Specification Form for Safety-Instrumented Fire and Gas System

Complete this form and click the request pricing button below to receive a quotation.1
  SI-FGS Type
FGS 1100 Safety-Instrumented Fire & Gas System based on Siemens Quadlog
FGS 1400 Safety-Instrumented Fire & Gas System based on Siemens S7-400 HF
Safety Instrumented Fire & Gas System based on
  PLC Processors
Simplex Processor
Redundant Processors
  PLC I/O Modules
Centralized I/O Modules
Distributed Remote I/O Modules (FGS 1400 Only)
Number of Zones
# of Zones
  Initiating Devices
# Initiating Device Circuits per Zone (Up to 20 devices per circuit max)
# of 2-wire dry contact inputs
# of 4-wire dry contact inputs
# of Analog Inputs
  Notification Appliances
# Notification Appliance Circuits Zone (Each circuit can support up to 10 Amps)
Specify Notification Device control voltage or contact closure (cc)
  Suppression Devices
# Suppression Device Circuits per Zone
Specify Suppression Device control voltage or contact closure (cc)
  Fire Safety Function Circuits
# Fire Safety Function Circuits per Zone
  Gas Detection Cicruits
# Gas Detection Circuits in Zone
  Gas Detection Functionality
IR Flame Detectors
Combustible Gas Detectors
Toxic Gas Detectors
Specify Other
  Battery Backup System
24 Hours Battery Backup with FM Approved Battery System
4 Hours Battery Backup with FM Approved Battery System
Batterry Backup System Provided By Others (Requires re-certification by FM)
  Unit Operation
Offshore Processing Facility
Onshore Processing Facility
Refinery
Semi-Conductor
Petro-Chemical Facility
Specify Other
  Enclosure
Wall Mount NEMA 12 Painted Carbon Steel Enclosure
Wall Mount NEMA 4X Stainless Steel Enclosure
Specify Other
  Enclosure Environmental Conditioning
None
Electrical Heater
Pneumatic Cooling
Electrical Cooling
  Area Classification (Where FGS Panel will be mounted)
General Purpose
Class I, DIV 2
Class I, DIV 1 – Type Z Purge
  Field Wiring Design
None: Will use existing field wiring
General Purpose
Explosion Proof
Intrinsically Safe - Requires Factory consultation
  Operator Interface
Local Mounted Flat Panel – Siemens TP370 (FGS 1100 only)
Local Flat Panel PC with Safety Matrix
Specify Other
  Field Device Voltage
24 VDC
Other – Requires Factory consultation
  Design Engineering Options2
None
AE Solutions to Specify and Supply Field Devices – Fire / Gas Sensors and / or Final Elements
AE Solutions to Provide Electrical / Controls Engineering Design for Installation of field devices
  Safety Instrumented System Engineering Options
None
Onsite Safety Instrumented System Training
Hazards Analysis / Safety Integrity Level Selection
Safety Requirements Specification
Safety Integrity Level Verification Calculations
Functional Test Plans
SI-FGS Configuration provided by AE Solutions - Required for FM approval
  Product Certifications
FM - NFPA 72
FM - Gas Certification
None
Name*  
Title*  
Company*  
Email*  
Phone*  
Project Reference*  
Requesting*  
Project Type*  
Purchase Date*  
Nuisance Trip Cost*   The cost of a nuisance trip is a determining factor on the degree of FGS redundancy. Expensive down time can easily justify the cost of redundant architecture.
Questions/Comments  

   
(After submitting this form you will be prompted to print this page for your records.)
   
* Required Fields

1 Client to provide I/O List, P&ID, or Wiring Diagram(s) along with request for quotation in order to allow AE Solutions to confirm extended pricing.

2 AE Solutions shall contact client to obtain additional information to support developing pricing for this requested option.