Application / Specification Form for Safety-Instrumented BMS

Complete this form for each BMS or indicate quantity if all are of the same design and click the request pricing button below to receive a quotation.1
Specify Quantity
  SI-BMS Type
BMS 1300 Safety Instrumented BMS based on Siemens S7-300F
BMS 1400 Safety Instrumented BMS based on Siemens S7-400HF
BMS xxxx Safety Instrumented BMS based on
  Number of Burners
Single Burner
Multiple Burner
  Igniter Type
Class 1 Igniter (Rated at > 10% of main burner max fuel flow for light-off in any conditions)
Class 2 Igniter (Rated at 4 to 10% of main burner max fuel flow for light-off in specific prescribed conditions)
Class 3 Igniter (Rated at < 4% of main burner max fuel flow for light-off of gas or oil under prescribed conditions)
Pilot Fuel
Oil Firing
Natural Gas Firing
Alternate Fuel Firing
No Pilot
  Main Burner Fuel
Oil Firing
Oil Firing - Manual Oil Gun Retraction
Oil Firing - Automatic Oil Gun Retraction
Natural Gas Firing
Alternate Fuel Firing
Simultaneous Steady State Firing of Multiple Fuels
Online Transfer Between Fuels
  Flame Scanner(s)
One Scanner Detects Both Pilot and Main Flame
One Scanner Detects Main Flame Only
One Scanner Detects Pilot Flame Only
Redundant Scanners Both of Which Detect Pilot and Main Flame
None
Specify Other  
  Unit Operation
Boiler
Process Heater
Dryer
Kiln
Furnace
Oven
Incinerator
Calciner
HRSG
Reboiler
Oxidizer
Vaporizer
Specify Other  
  Enclosure
None - Mounted On Sub-Panel To Be Installed In Client Enclosure
Wall Mount NEMA 4 Painted Carbon Steel Enclosure (48"W x 36"H x 16"D)
NEMA 4X Stainless Steel Enclosure (48"W x 36"H x 16"D)
Specify Other  
  Enclosure Environmental Conditioning
None
Electric Heater
Pneumatic Cooling
Electric Cooling
  Area Classification where BMS 1300 will be mounted
General Purpose
Class 1, Div 2
Class 1, Div 1 - Type Z Purge
  Operator Interface
None
Local Mounted Flat Panel - Siemens TP270 or Specify Other  
Remote Mounted Flat Panel - Siemens TP270 or Specify Other  
Push Buttons / Pilot Lights
Graphics for PCS7 or Specify Other  
  Field Device Voltage
24 VDC
120 VAC - Contact Factory to discuss options
  Field Device Input Module
Transmitters with Analog Input Module
Discrete Switches with Digital Input Module
  Design Engineering Options3
None
Specify and Supply Igniter
Specify and Supply Flame Scanner(s)
Specify and Supply Fuel Block Valves
Specify and Supply Field Devices - Switches / Transmitters
Provide Electrical / Controls Engineering Design for Installation of Field Devices
Provide Mechanical / Piping Engineering Design for Fuel Trains
  Safety Instrumented System Engineering Options3
Onsite Safety Instrumented System Training
Hazards Analysis / Safety Integrity Level Selection2
Safety Requirements Specification2
Safety Integrity Level Verification Calculations2
Functional Test Plans
SI-BMS Configuration Provided (Required)
All Of The Above Safety Instrumented System Engineering Options
  Product Certifications
None - Meets basic NFPA 85 or NFPA 86 code
FM 7605 - Safety Instrumented Burner Management System
TSSA - For Canadian Installations
  Combustion Control System
None
Parallel Positioning (Jackshaft design)
Fully metered and cross limited
Excess oxygen trim. Analyzer exists AE Solution to specify and provide
Name*  
Title*  
Company*  
Email*  
Phone*  
Project Reference*  
Requesting*  
Project Type*  
Purchase Date*  
Nuisance Trip Cost*   The cost of a nuisance trip is a determining factor on the degree of BMS redundancy. Expensive down time can easily justify the cost of redundant architecture.
Questions/Comments  

   
(After submitting this form you will be prompted to print this page for your records.)
   
* Required Fields

1 A formal proposal typically requires submission of I/O list, P&ID and/or wiring diagrams.

2 To properly quote a SI-BMS may require a formalized risk analysis and ranking in order to develop SIL
   requirements that will drive system architecture.

3 Quoted separately upon definition.